WhatsApp
Liquid Chromatograph Mass Spectrometer NLMS-101

Liquid Chromatograph Mass Spectrometer NLMS-101

Liquid Chromatograph Mass Spectrometer NLMS-101 features an ultra-high-pressure gradient pump system for precise solvent delivery. It comes with a column oven that controls temperatures from RT +5 °C to 90 °C. Our unit houses up to six chromatographic columns, each measuring 250 mm in length. It uses a triple quadrupole mass analyzer built with high-precision molybdenum. This system enables real-time status monitoring for continuous performance tracking.


$175,050.00

Catalog

Specifications

Working temperature range 18 to 25 °C
Working humidity range 20 to 60%RH
Gradient pump Dual solvent lines (A/B or C/D) with solvent selection valve
Vacuum degasser for each pump line (A/B)
Gradient pump flow rate 1 to 4000 µL/min
Gradient pump flow rate accuracy ≤1%
Gradient pump flow rate precision ≤0.075% RSD
Gradient pump max pressure ≥18,850 psi
Automatic sample injection mode Full loop, Partial loop, Microliter pickup
Automatic sample injection repeatability Full/Partial <0.3% RSD; Microliter <1.0% RSD
Cross contamination <0.05%
Max sample capacity 384 vials; Standard: 96 vials
Column oven temperature range RT +5 °C to 90 °C
Column oven temperature mode Flow phase preheating + forced air circulation
Column oven capacity 6 × 250 mm columns
Ion source Orthogonal vertical spray
Anti-contamination, Low noise
Nitrogen gas: Atomizing (0 to 2 L/min), Desolvation (0 to 15 L/min)
Vacuum interface Blowback gas: Nitrogen, 0 to 5 L/min
4-stage differential vacuum system
Ion transmission system Multi-quadrupole focusing
Mass analyzer type Triple quadrupole
Quadrupole material High-purity Molybdenum
Collision cell Axial acceleration, Nitrogen gas (≥99.999%)
Mass stability <0.1 amu over 24 hours
Scanning speed ≥20,000 amu/s
Mrm channels 300/s
Mass range 5 to 1000 amu
Scan modes Full Scan, SIM, Product/Precursor Ion, Neutral Loss, MRM, Polarity Switch
Vacuum system Mechanical + turbo molecular pump
Operating system Windows XP or above
Control functions Full control of LC and MS systems
Data handling Built-in data processing, reporting, and quantification
Database Spectrum database creation and retrieval
Power supply Five sets of single-phase AC(220 ± 20) V, 10A, 50 Hz
Product dimension 1000×700 ×600mm
Packing dimension 1400×680×920mm
1570×970×1020mm
810×700×790mm
Net weight 120 kg
Gross weight 428 kg

Features

  • Advanced ion transmission
  • Anti-contamination ion source
  • High scanning speed
  • Multiple scan modes
  • Automated data processing
  • Minimal cross-contamination
  • Power-off protection system
  • High-capacity sample tray

Applications

  • Liquid Chromatograph Mass Spectrometer NLMS-101 is used for precise qualitative and quantitative analysis of complex chemical mixtures at trace levels. It is widely applied in pharmaceuticals, environmental monitoring, food safety testing, and clinical research laboratories.

Standard Accessories

MS accessory kit (overseas version)

LC accessory kit (overseas version)

Vacuum mechanical pump EMP 70

Flow injection pump

Liquid phase ultra-high pressure infusion pump (spark)

Liquid waste module

Solvent tray

Optional Accessories

Nitrogen generator-NG-200 membrane separation type 

Nitrogen generator maintenance kit 

European standard adapter plug & 2500W & 10A & 250V & 50×40×43mm & blister/with switch 

European standard three-core power cord & length 2m (4stick)

Ask Expert

FAQ for Liquid Chromatograph Mass Spectrometer NLMS-101

1: How does the Liquid Chromatograph Mass Spectrometer NLMS-101 ensure consistent performance?

Our Liquid Chromatograph Mass Spectrometer offers real-time system monitoring and automated control through integrated software. This ensures that the instrument operates at optimal conditions throughout the analysis.

2: Does the Liquid Chromatograph Mass Spectrometer NLMS-101 support flexible sample injection modes?

Yes, our Liquid Chromatograph Mass Spectrometer provides three injection modes: full loop, partial loop, and microliter pickup. This flexibility helps in optimizing sample volume and improving injection precision based on specific application needs.

3: How does the Liquid Chromatograph Mass Spectrometer reduce sample contamination?

The Liquid Chromatograph Mass Spectrometer incorporates a dedicated exhaust device and anti-pollution ion source design. These prevent backflow and reduce memory effects, ensuring cleaner results and a longer instrument lifespan.

4: How often does the Liquid Chromatograph Mass Spectrometer NLMS-101 require maintenance?

Routine maintenance is minimal and typically involves periodic cleaning of key components like the ion source and vacuum interface. Following the manufacturer’s maintenance schedule helps ensure stable performance over time.

5: What steps help extend the life of the mechanical pump?

The Liquid Chromatograph Mass Spectrometer features an exhaust device that reduces contamination and backflow, lowering the load on the mechanical pump. Regularly checking pump oil levels and changing it as needed can further extend its service life.

Related Models Of LC-MS

Labnics © 2025. All Rights Reserved.