Digital Colony Counter NCOC-101

Digital Colony Counter NCOC-101

Digital Colony Counter NCOC-101 supports petri dishes from Ø50 to 150 mm and provides a magnification range of 3 to 9 times. It features a frameless magnifying glass for enhanced colony visibility. This unit provides adjustable sensor sensitivity for flexible use. It includes manual correction buttons to adjust for missed or repeated counts. Our digital colony counter has a pressure-sensitive glass surface for accurate and responsive counting.


$1,038.00

Catalog

Specifications

Counting Capacity 0 to 999 or 0 to 9999
Compatible Petri Dish Ø50 to 150 mm
Lighting Type White LED Array
Digital Display 3-digit / 4-digit LED
Magnification Range 3 to 9 times
Protection Class IP21
Maximum Relative Humidity 80%
Operating Temperature Range 5 to 50°C
Power Consumption 40 W
Power Supply AC 100 to 240V (50/60 Hz)
Product Dimensions 360 × 300 × 180 mm
Packaging Dimension 520 × 450 × 390 mm
Net Weight 8 kg
Gross Weight 11 kg

Features

  • Upper light source
  • Supports various culture dishes
  • Adjustable LED lighting
  • Wide voltage range
  • Compact structure

Applications

  • Digital Colony Counter NCOC-101 is suitable for microbiology labs, research centres, pharmaceutical testing, food safety analysis, and quality control units for accurate colony counting on various culture media.

Standard Accessories

Counting pen/probe × 1 pc

Power adapter × 1 pc

Magnifying lens (3×) × 1 pc

Glass or plastic Petri dish holder (Ø155 mm) × 1 pc

Ask Expert

FAQ for Digital Colony Counter NCOC-101

1: How does the Digital Colony Counter NCOC-101 enhance colony visibility during counting?

The Digital Colony Counter NCOC-101 is equipped with a magnification range of 3 to 9 times and a frameless magnifying glass that provides a clear, unobstructed view of colonies for precise counting.

2: Can I adjust the sensitivity of the sensor on the Digital Colony Counter NCOC-101?

Yes, the Digital Colony Counter NCOC-101 features adjustable sensor sensitivity, allowing users to fine-tune detection based on the density and type of colonies being analyzed.

3: What happens if the Digital Colony Counter NCOC-101 misses or repeats a count?

Our Digital Colony Counter NCOC-101 includes manual correction buttons that allow users to easily adjust the count in case of missed or repeated entries, ensuring accurate and reliable results throughout the counting process.

4: Does the Digital Colony Counter NCOC-101 provide proper illumination for accurate colony detection?

The Digital Colony Counter NCOC-101 features an adjustable white LED array with an upper light source that provides uniform, bright illumination for clear and accurate colony visibility.

5: What should I do if the Digital Colony Counter NCOC-101 does not respond when touched?

If the Digital Colony Counter NCOC-101 is unresponsive, check the power connection and ensure the unit is switched on. Also, verify that the pressure-sensitive glass surface is clean and free from debris.

6: What lighting system is used in the Digital Colony Counter, and how does it help?

Our Digital Colony Counter features a white LED array with an upper light source and adjustable brightness. This provides uniform illumination across the entire dish, enhancing contrast between the colonies and the culture media, which leads to more precise counting.

7: How does the pressure-sensitive surface benefit the Digital Colony Counter’s performance?

The Digital Colony Counter uses a pressure-sensitive glass surface that detects each touch accurately and quickly. This ensures responsive counting with minimal effort, reduces the risk of input errors, and enhances the overall efficiency of the colony counting process.

8: Can the Digital Colony Counter correct errors during the counting process?

Yes, the Digital Colony Counter includes manual correction buttons that enable users to make adjustments in real-time. This is particularly useful when a colony is missed or counted twice, allowing for immediate correction without needing to restart the process.

9: What precautions should I take while cleaning the Digital Colony Counter?

Always disconnect the Digital Colony Counter from the power source before cleaning. Avoid using excessive liquid near the LED display or sensor surface, and never allow moisture to enter the internal components, as this can impact the sensor accuracy or damage the electronics.


Digital Colony Counter NCOC-101

Digital Colony Counter NCOC-101


Related Models Of Digital Colony Counter

Labnics Digital Colony Counter features a frameless magnifying glass for clear observation during colony counting. It includes adjustable LED lighting to provide optimal illumination for accurate results. These units are designed with a compact structure for easy placement and efficient use. They come with manual correction buttons for quick count modification. Our digital colony counter offers adjustable sensor sensitivity for accurate and reliable detection.