Vertical Autoclave NVA-402

Vertical Autoclave NVA-402 features a 65 L capacity with a sterilization temperature range of 105 to 135°C. It includes a digital touch screen with an adjustable angle for real-time parameter display. Our unit has multi-level cold air discharge and pressure relief options. It supports USB export for convenient data backup and transfer. This autoclave offers advanced water level detection for safe and efficient operation.


$6,800.00

Catalog

Specifications

Capacity 65 L
Environment Temperature 5 to 40°C
Environment Humidity 20 to 80%RH
Sterilization Temperature 105 to 135°C
Temperature Fluctuation Less than ±1°C
Temperature Uniformity Less than or equal to ±1°C
Melting Temperature 60 to 100°C
Heat Preservation Temperature 40 to 60°C
Sterilization Timer Range 0 to 240 minutes
Melting Timer Range 0 to 600 minutes
Heat Preservation Timer Range 0 to 100 hour
Design Pressure 0.39 MPa
Working Pressure 0.24 MPa
Cavity Size Ø380 × 610 mm
Number of Baskets 2
Power Consumption 3.2 kW
Power Supply 220 ± 10%V, 50 ± 2% Hz
Dimensions 605 × 513 × 915 mm
Net weight 85 kg
Gross weight 98 kg

Features

  • Alarm and data recording system
  • Safety protection mechanisms
  • User-friendly interface
  • Boiling point setting function
  • One-click exhaust and drainage
  • Self-locking and interlocking

Applications

  • Vertical Autoclave NVA-402 is ideal for healthcare, research, and industry, ensuring effective sterilization of medical instruments, lab equipment, culture media, and packaging materials.

Optional Accessories

Biosafety filter

Filter element (consumables)

Verification lead

Printer

Liquid tray

Ask Expert

FAQ for Vertical Autoclave NVA-402

1: How user-friendly is the control interface?

Our Vertical Autoclave features a digital touchscreen with an adjustable viewing angle, offering a real-time display of operating parameters. The interface is intuitive, with one-click functions for exhaust and drainage to simplify operation.

2: Is there a boiling point setting function in this Vertical Autoclave NVA-402?

Yes, our Vertical Autoclave includes a boiling point setting function, enabling precise control during sterilization cycles involving sensitive materials.

3: How is cold air discharged from the Vertical Autoclave NVA-402?

The Vertical Autoclave is equipped with a multi-level cold air discharge system. This feature ensures thorough removal of cold air before the sterilization process begins, ensuring uniform heating and sterilization quality.

4: What checks should be done before each use?

Before operating, inspect the chamber for any leftover items or contamination. Also, check the water level, the condition of the door seal, and confirm that the previous cycle completed without error messages.

5: Do I need to descale the autoclave chamber?

Yes, if hard water is used, mineral deposits can accumulate. Descaling should be done monthly or as needed using a manufacturer-approved descaling solution to ensure optimal heating and steam generation.

6: Is the Vertical Autoclave suitable for use in laboratories with limited space?

Yes, the vertical design is especially suited for compact spaces. It takes up minimal floor area while offering sufficient internal volume for sterilizing multiple items at once. This makes it a preferred choice in many research and clinical labs.

7: Can the Vertical Autoclave handle different types of loads, like liquids and instruments?

Yes, our Vertical Autoclave is designed to sterilize a wide range of materials, including liquids, surgical instruments, culture media, and lab glassware. With adjustable temperature and time settings, it adapts easily to various sterilization needs.

8: How durable is the construction of the Vertical Autoclave?

The Vertical Autoclave is built with high-grade stainless steel that resists corrosion and ensures a long operational life. The rugged outer body and quality internal components are designed to withstand repeated high-temperature cycles. This ensures dependable performance over time.

9: Is the Vertical Autoclave easy to maintain?

Routine cleaning and basic maintenance, like water tank refilling and gasket checks, are straightforward. The design allows easy access to internal parts for inspection. With proper care, it continues to perform efficiently with minimal servicing.


Vertical Autoclave NVA-402

Vertical Autoclave NVA-402

Related Models Of Vertical Autoclaves

Vertical Autoclave are designed with built-in safety mechanisms that prevent damage and ensure user safety. Our vertical autoclaves are designed to operate efficiently, ensuring minimal energy consumption. They feature intuitive controls and clear displays for easy monitoring. These autoclaves are crafted from high-quality stainless steel, providing exceptional durability. They include an electronic lock system that secures the door during the sterilization cycle.