Automated Solid Phase Extractor NSPE-101 operates with dual channels, offering nitrogen-purged extraction at up to 120 mL/min flow rate. This system ensures fast solvent switching and efficient waste control during extractions. Our extractor configuration includes an adjustable sample rack with enhanced cartridge alignment. It maintains consistent function with minimal handling and limited tuning requirements. This unit offers stable performance with smart detection and intuitive method settings.
| Channels |
2 |
| Sample Volume |
0.1 mL to 20 mL |
| Sample Tube Volume |
10 to 20 mL, customizable |
| Column Pressure |
0 to 145 psi |
| Receiving Volume |
10 mL / 15 mL, other customized |
| Channel Independent Control |
Support |
| Pump Flow Rate |
0.1 to 120 mL/min |
| Sample Pump |
Precision Continuous Sample Pump |
| Types of Solvents |
8-seed, 500 mL Solvent Bottle |
| Puncture Sampling |
Supporting |
| Loading Mode |
X/Y/Z Three-Dimensional Manipulator |
| Accuracy of Manipulator |
0.01 mm |
| Sealing Technology |
Docking Seal & Pan-plug Seal |
| Extraction Mode |
Positive Pressure Extraction |
| Pressure Sensing |
Support, Overvoltage Alarm, Editable (5 to 145 psi) |
| Column Drying Method |
Nitrogen Purge |
| Waste Collection |
Branch collection, 3 channels |
| A/B in Series |
Support, A/B Pillar |
| Cleaning Mode |
Nitrogen, solvent, and stirring cleaning |
| Liquid Level Following |
Support |
| Solvent Residual Capacity |
Solvent deficiency hints |
| Working Temperature |
0 to 40°C |
| Working Humidity |
10 to 85% |
| Power Consumption |
100 W |
| Power Supply |
220/110V, 50/60Hz |
| Dimensions (H×W×D) |
680×580×670 mm |
FAQ for Automated Solid Phase Extractor NSPE-101
1: Does the Automated Solid Phase Extractor NSPE-101 include any features that help reduce human error during setup?
Labnics Automated Solid Phase Extractor includes guided prompts and pre-programmed protocols to help users set up extractions consistently without manual adjustments.
2: Is it possible to use the Automated Solid Phase Extractor NSPE-101 for extended runs without system resets?
Yes, the dual-channel design and solvent level tracking allow continuous operation over longer sessions without interruptions.
3: How does Automated Solid Phase Extractor NSPE-101 manage leftover solvents or waste more efficiently?
Our extractor uses a branched waste system and sensor-based monitoring to handle excess fluid and prevent overflow.
4: Are the components in contact with solvents resistant to corrosion or buildup?
Labnics uses chemically resistant materials in flow paths and valves to reduce residue formation and ensure long-term durability.
5: Does the Automated Solid Phase Extractor NSPE-101 require frequent recalibration between uses?
Automated Solid Phase Extractor is designed with stable internal sensors, so routine recalibration isn’t required unless parameters are manually altered.
6: What features make Labnics Solid Phase Extractors efficient for routine use?
Labnics Solid Phase Extractors include pressure control, solvent routing, and automation to streamline consistent extractions across workflows.
7: Are Labnics Solid Phase Extractors compatible with all common cartridge types?
Our Solid Phase Extractors are built to support standard SPE cartridges and multiple solvent lines for versatile sample preparation.
8: How do Labnics Solid Phase Extractors reduce manual intervention?
These use programmable steps, auto-cleaning functions, and flow control to minimize user interaction and prevent operation errors.
9: Can Labnics Solid Phase Extractors maintain consistent output over time?
These are designed with integrated sensing and method storage to ensure long-term reliability and repeatable extraction performance.