Real-Time Thermal Cycler NRTC-101 can handle up to 96 PCR tubes with a volume of 0.2ml each for high throughput. It offers a temperature range of 4°C to 100°C with an accuracy of ± 0.1°C for precise results. Features 12 gradient temperature columns and 6 zones for precise annealing control. Utilizes LED excitation source and PD device for precise fluorescence detection in PCR assays. Equipped with a 7-inch touch screen for easy and intuitive operation.
$15,250.00
Specifications
| Sample Capacity | 96 × 0.2ml |
| Consumable Type | 0.2ml single tube 8 × 0.2ml tube strip 96-well plate |
| PCR Volume Range | 15 to 120μL |
| Temperature Range | 4°C to 100°C |
| Temperature Accuracy | ± 0.1°C |
| Temperature Uniformity | ± 0.2°C |
| Temperature Control Technology | 6-zone independent temperature control combined with thermal compensation tech to reduce edge effect |
| Working Temperature | 15 to 30°C |
| Storage Temperature | -20 to 55°C |
| Ambient Relative Humidity | ≤ 85% |
| Ramp Heating Rate | 4.2°C/s |
| Ramp Cooling Rate | 4.2°C/s |
| Gradient Temperature Columns | 12 |
| Gradient Temperature Range | 1°C to 32°C |
| Gradient Temperature Zones | 6 |
| Gradient Temperature Set Range | 30°C to 100°C (Room temperature is lower than 28°C) |
| Excitation Source | LED |
| Detection Device | PD |
| Light Propagation Medium | Dual-96 high-temperature resistant optical fibres for Space |
| Detection Channels | 5 (Expandable to 6) |
| Excitation Range | 1st Channel: 470nm ±10nm 2nd Channel: 525nm ±10nm 3rd Channel: 570nm ±10nm 4th Channel: 620nm ±10nm 5th Channel: 670nm ±10nm 6th Channel: Customizable |
| Detection Range | 1st Channel: 512nm-528nm 2nd Channel: 562nm-578nm 3rd Channel: 612nm-628nm 4th Channel: 662nm-678nm 5th Channel: 702nm-718nm 6th Channel: Customizable |
| Dye Compatibility | FAM, SYBR Green, Eva Green, LCGreen, Fluorescein, VIC, HEX, TET, Cy3, JOE, Alexa555, ROX, Cy3.5, Texas Red, Cy5, LC Red640, Cy5.5, LC Red705, Tamara |
| Detection Sensitivity | ≥ 1 copy |
| Confidence Coefficient | 0.999 |
| Sensitivity | Allowed 1.5-fold in a single reaction |
| Sample Detection Repeatability | CV ≤ 1% |
| Linear Range | 1 to 1010 |
| Sample Linearity | ≥ 0.99 |
| Control Method | Touch screen operation |
| Software Function | Real-time monitoring Multiple quantification Melting curve analysis Gene mutation detection Genotyping (Taqman probe) Tm value determination Quality control graphics |
| Output | EXCEL/WORD/PDF |
| Safety Compliances | CE/ISO9001/ISO13485 |
| Power Supply | 100-240V, 50-60Hz, 1500VA |
| Dimensions (W × D × H) | 540 × 351 × 310 mm |
| Packaging Dimensions | 850 × 600 × 650 mm |
| Net Weight | 20 kg |
| Gross Weight | 48 kg |
Features
Applications
Standard Accessories
Power cord × 1pcOptional Accessories
Customized 6th channelAsk Expert