WhatsApp
Gradient Thermal Cycler NGTC-300

Gradient Thermal Cycler NGTC-300

Gradient Thermal Cycler NGTC-300 has a capacity of 96×0.2 ml tubes and a temperature range from 4 to 99.9°C. It features a user-friendly 8-inch full-color LCD for intuitive operation. This unit includes a built-in gradient calculator to simplify the optimization of annealing temperatures for various primer sets. It provides both test tube and block temperature control modes to suit diverse needs. Our thermal cycler incorporates a hot cover designed for optimal heat retention.


$3,800.00

Catalog

Specifications

Capacity 96×0.2ml
Temperature range 4 to 99.9°C
Maximum heating rate 4.5°C/s
Maximum cooling rate 4°C/s
Temperature uniformity ±0.25°C
Temperature accuracy ±0.20°C
Temperature display resolution 0.1°C
Temperature control method Block/Tube
Temperature change rate 0.1 to 5°C
Gradient temperature uniformity ±0.3°C
Gradient temperature accuracy ±0.3°C
Gradient temperature range 30 to 99.9°C
Gradient setting range 0.1 to 30°C
Hot cover temperature range 30 to 110°C
Single-step time range 1 to 59mins 59secs
Hot lid height Adjustable
Maximum no. of steps 30
Maximum no. of programs 99
Time increment/decrement -599 to 599 secs
Temperature increase/decrease -9.9 to 9.9°C
Program pause function Yes
16°C insulation Forever
Display 8-inch LCD screen
Storage capacity >100
Communication interface USB 2.0, LAN
Power supply AC100 to 240V, 6.6 to 3.1A, 50/60Hz
Fuse 250V, 8A Ф5×20
Dimension 390×270×255mm
Net weight 8.5 kg

Features

  • Fast heating/cooling rates
  • USB & LAN support
  • Large program storage
  • Adjustable lid height
  • User login protection
  • Air-cooled ventilation system
  • Tube/block mode switch
  • One-click open button

Applications

  • Gradient Thermal Cycler NGTC-300 is used for gene amplification in scientific research, including qualitative PCR, endpoint quantitative DNA amplification, and gene chip analysis. It is applied in laboratories focused on molecular biology, genetics, biotechnology, and clinical diagnostics.

Ask Expert

FAQ for Gradient Thermal Cycler NGTC-300

1: How fast is the heating and cooling?

Our Gradient Thermal Cycler offers a maximum heating rate of 4.5°C/s and a cooling rate of 4.0°C/s. It significantly reduces overall run time, which is perfect for time-sensitive experiments.

2: What security features does the Gradient Thermal Cycler NGTC-300 have?

Our Gradient Thermal Cycler includes user login, password protection, and authority management. You can assign roles and restrict access to safeguard data and prevent unauthorized changes.

3: Is the Gradient Thermal Cycler NGTC-300 suitable for high-throughput labs?

Absolutely! With its large storage capacity, fast heating/cooling rates, and multiple program options, it is well-suited for high-throughput PCR, DNA amplification, and other genomic applications.

4: How can I ensure the Gradient Thermal Cycler NGTC-300 stays in good working condition?

Regularly check for any dust or debris in the air intake and exhaust areas. It is also helpful to ensure that the cooling system is unobstructed and that the thermal cycler is placed in a well-ventilated space to avoid overheating.

5: How do I clean the hot lid?

The hot lid can be cleaned using a non-abrasive cloth and mild detergent. Avoid using harsh chemicals that could damage the surface. Regular cleaning of the lid prevents residue buildup and ensures proper heat retention.

6: Is the Gradient Thermal Cycler NGTC-300 suitable for high-temperature PCR applications?

Yes, our Gradient Thermal Cycler can reach temperatures up to 99.9°C, making it ideal for high-temperature PCR applications such as denaturation. Its precise control ensures that the high temperatures do not compromise the integrity of your samples.

7: Can I run different sample sizes with this Gradient Thermal Cycler?

Yes, the Labnics Gradient Thermal Cycler supports various sample capacities, which is perfect for both small-scale and high-throughput experiments. You can use different formats, like 0.2 mL tubes and 96-well plates, depending on the project. This flexibility makes it very versatile in the lab.

8: Can I monitor the status of my PCR run in real-time?

Yes, our Gradient Thermal Cycler provides real-time status updates via the touchscreen interface, so you can check the progress of your run at any time. It shows detailed information such as current cycle, temperature profile, and estimated time to completion. This feature ensures that you are always aware of how your experiment is progressing.

9: Are there any routine checks I should perform on the Gradient Thermal Cycler?

It is recommended to routinely inspect the thermal cycler for any signs of wear or damage, especially the hot lid and temperature sensors. Check for consistent temperature readings and ensure all software settings are correct before starting an experiment.

10: Can the Gradient Thermal Cycler be used for high-throughput applications?

Yes, it is well-suited for high-throughput workflows due to its ability to handle multiple samples simultaneously in different formats, including 96-well and 384-well plates. This makes it perfect for labs that need to process large numbers of samples in one batch while maintaining precise temperature control.

Related Models Of Gradient Thermal Cycler

Labnics Gradient Thermal Cyclers offer various sample capacities to accommodate different experimental needs. They deliver consistent and accurate thermal conditions across all wells for reproducible PCR results. These units feature a user-friendly interface with intuitive programming and touchscreen navigation. They provide a large data storage capacity for saving and managing multiple protocols. Our thermal cyclers include built-in safety mechanisms to ensure secure operation.

Labnics © 2025. All Rights Reserved.