Ethylene Oxide Sterilizer NEOS-104 features a water storage capacity of 5 L and operates at a sterilization pressure of -80 kPa. It has pneumatic control for smooth and safe door operation. Our unit is equipped with a colour touchscreen for easy control and monitoring. It includes an efficient water detoxifier for safe gas neutralization. This sterilizer supports wireless access for convenient operation and fault alerts.


$800.00

Catalog

Specifications

Capacity 900 L
Water Storage Capacity (Humidification Bottle) 5 L
Exhaust Mode Direct exhaust, Floor drain
Sterilization Pressure -80 Kpa
Sterilization Humidity 40 % to 80 %
Sterilization Cycle At 55°C: 8 to 15 hours
Aeration Time At 37°C: 6 hours
Internal Material SUS304
Print type Number / Figure
Loading mode Vehicle
Power Consumption 10 KW
Power Supply 220 V, 50/60 Hz
Internal Dimension 1290 × 700 × 1000 mm
External Dimension 1300 × 1450 × 1850 mm
EO Cartridge 180 g × 3
Weight 1000 kg

Features

  • Automatic safety alarms
  • Hot air analysis
  • Built-in vacuum pump
  • USB storage
  • PLC circuit design

Applications

  • Our Ethylene Oxide Sterilizer is suitable for sterilizing medical instruments and devices in healthcare facilities, laboratories, and pharmaceutical industries using ethylene oxide gas.

Ask Expert

FAQ for Ethylene Oxide Sterilizer NEOS-104

1: What safety measures protect the Ethylene Oxide Sterilizer from overheating?

If the sterilization temperature exceeds preset limits, the Ethylene Oxide Sterilizer automatically stops heating and activates alarms to safeguard sterilization items and equipment.

2: Can the Ethylene Oxide Sterilizer NEOS-104 be monitored remotely?

Yes, the Ethylene Oxide Sterilizer supports mobile app control for remote monitoring and operation. Fault alarms are sent directly to users and service centers to enable quick maintenance responses.

3: How does the Ethylene Oxide Sterilizer remove residual gas after sterilization?

The Ethylene Oxide Sterilizer employs hot air analysis combined with fresh air flushing under negative pressure to effectively and safely eliminate residual gas. The removal process features adjustable settings to ensure thorough and customizable sterilization.

4: Does the Ethylene Oxide Sterilizer NEOS-104 record sterilization data?

Our Ethylene Oxide Sterilizer features a thermal printer for real-time data printing and stores sterilization records permanently on a USB disk. It also has a memory function that allows cycle continuation after power interruptions.

5: What should I do if the Ethylene Oxide Sterilizer shows a fault alarm?

Check for common issues like chamber door not fully closed, temperature or humidity deviations, or power interruptions. The system will display error messages on the screen for easy troubleshooting.

6: How does the Ethylene Oxide Sterilizer ensure door safety and ease of use?

he Ethylene Oxide Sterilizer uses a pneumatic door locking system that automatically locks the door during sterilization and unlocks only after the cycle finishes. This automatic operation prevents accidental door openings, enhances user safety, and saves operator effort by eliminating manual handling.

7: What safety measures prevent ethylene oxide gas leakage during sterilization?

Our sterilizer maintains a negative pressure environment inside the chamber to prevent gas from escaping. If any leakage occurs, the system automatically initiates a cleaning phase to remove residual gas and simultaneously triggers audible and visual alarms to alert operators to the issue, ensuring both user safety and environmental protection.

8: What materials and components contribute to the durability and safety of the Ethylene Oxide Sterilizer?

The sterilizer is constructed with corrosion-resistant stainless steel for both the chamber and exterior. It uses durable sealing rings and valves designed for long life and safety. The vacuum pump is engineered to avoid sparks or static electricity, further enhancing operational safety.

9: How is sterilization data recorded in the Ethylene Oxide Sterilizer?

The sterilizer offers real-time printing of cycle data via an integrated thermal printer, allowing immediate access to operation records. Additionally, all sterilization data is securely stored on a USB device, providing a permanent and easily retrievable archive for future reference and documentation.


Ethylene Oxide Sterilizer NEOS-104

Ethylene Oxide Sterilizer NEOS-104


Related Models Of Ethylene Oxide Sterilizer

Labnics Ethylene Oxide Sterilizers feature an integrated gas purging system for the safe removal of residual gases. These units are constructed with corrosion-resistant stainless steel, ensuring durability and easy maintenance. They are equipped with a digital display for clear monitoring and precise control of sterilization parameters. They include a safety interlock to prevent accidental access during operation. Our ethylene oxide sterilizers offer data logging and printing options for efficient record-keeping.