ESR Analyzer NERA-101

ESR Analyzer NERA-101

ESR Analyzer NERA-101 can load up to 30 samples simultaneously for efficient batch processing. It uses an infrared sensor as the measuring principle for accurate and non-contact detection. This unit operates within a temperature range of 15°C to 32°C and humidity levels below 85%. It offers random access loading, allowing samples to be placed flexibly. Our analyzer displays information on a backlit LCD screen, ensuring clear visibility under various lighting conditions.


$3,800.00

Catalog

Specifications

Measuring principle Infrared sensor
Reading channels 30 available channels
Loading capability Up to 30 samples at a time
Tube specification 1.28ml/8×120 mm
Loading pattern Random
Measuring time 30 mins or 60 mins selectable
Throughput Up to 60 samples per hour
Result analysis Westergren ESR value (mm/hr)
Temperature compensation Refer to 18°C automatically (selectable)
Reading resolution 0.2 mm
Reproducibility <0.3% or ±2mm/1h
Result resolution 1mm/1h
Blood level range 50mm to 64mm
Operating temperature range 15°C to 32°C
Operating humidity <85%
Display LCD screen with backlight
Input Touch screen
Interface RS-232 serial port
Print Internal thermal recorder
Power consumption 50W
Power supply AC 220V/110V ±10%, 50/60 Hz
Dimension 400×300×200mm
Net weight 11.5 kg

Features

  • Built-in thermal printer
  • LIS/HIS connectivity
  • Barcode scanning support
  • High sample throughput
  • Real-time ESR curves
  • Multi-language support
  • High reading resolution

Applications

  • ESR Analyzer NERA-101 is used to measure the erythrocyte sedimentation rate, which helps detect inflammation and monitor disease progression. It is commonly used in clinical laboratories, hospitals, and diagnostic centers.

Standard Accessories

Power cable (1pc)

Optional Accessories

Scanner

Ask Expert

FAQ for ESR Analyzer NERA-101

1: Is it easy to read and print results from the ESR Analyzer NERA-101?

Absolutely. Our ESR Analyzer features a large backlit LCD screen that displays ESR values clearly, even in low-light environments. It also includes a built-in thermal printer for fast and convenient printouts, eliminating the need for external printing devices.

2: How long does it take to get results from the ESR Analyzer NERA-101?

The ESR Analyzer delivers results quickly, with a throughput of up to 60 samples per hour. Depending on your selected measurement time, results can be available in either 30 minutes or 60 minutes. This speed ensures that labs can efficiently handle a high volume of tests without delays.

3: Does ESR Analyzer NERA-101 support automatic temperature adjustment?

Yes, our ESR Analyzer features automatic temperature compensation referenced to 18°C, as per the Westergren method standard. This ensures accurate results regardless of environmental changes. You don't need to manually adjust for ambient temperature, which improves reliability and saves time.

4: Does the ESR Analyzer require frequent calibration?

The ESR Analyzer is designed for minimal maintenance and does not require frequent calibration. However, periodic checks are recommended to ensure long-term accuracy. It is calibrated to provide highly reliable results out of the box, with its infrared sensor technology contributing to precise measurements.

5: How does the ESR Analyzer ensure consistent performance over time?

The ESR Analyzer is built with high-quality components and advanced sensor technology to ensure stable, consistent performance over time. Its low-maintenance design means fewer issues with calibration or mechanical wear. Regular software updates and checks also ensure the analyzer remains in optimal working condition.

6: Is the ESR Analyzer easy to use?

Yes, the ESR Analyzer features a user-friendly interface with clear controls, making operation straightforward even for staff with minimal training. This helps speed up the lab workflow without complications.

7: Can the ESR Analyzer store and transfer test data?

Yes, our ESR Analyzer includes data management features such as internal storage and connectivity options. This makes it easy to save records and integrate with other systems for seamless reporting.

8: Can the ESR Analyzer handle multiple samples in a day?

Yes, our ESR Analyzer is built for high throughput, allowing labs to process multiple samples efficiently without compromising accuracy. This makes it ideal for busy clinics and diagnostic centers.

9: What basic maintenance tasks can users perform themselves?

Users can easily clean the sample holder and exterior surfaces after each use to prevent buildup. Checking for software updates and running calibration tests are also straightforward tasks that maintain performance.


ESR Analyzer NERA-101

ESR Analyzer NERA-101


Related Models Of ESR Analyzer

Labnics ESR Analyzer processes multiple samples quickly and efficiently for fast and reliable results. They offer large data storage capacity for extensive data management. These analyzers include a built-in printer for direct and effortless result printing. Our units feature user-friendly touchscreen interfaces for easy operation. They provide graphical representations of erythrocyte sedimentation for detailed analysis.