Bilirubin Meter NBLM-102

Bilirubin Meter NBLM-102

Bilirubin Meter NBLM-102 features a xenon flash lamp as a light source, ensuring precise measurement. This meter applies light reflection by comparing blue and green light to assess bilirubin levels. Our unit offers automatic calibration, with calibration displays such as “00.0” and “20.0 ±1”. It includes a three-digit LCD with freely switchable units between mg/dL and µmol/L. It supports 2 to 5 average measurements and allows at least 500 uses per charge.


$3,600.00

Catalog

Specifications

Detection method Light reflections, comparison of blue and green light
Light source Xenon flash lamp
Measuring times 500 times
Calibration function Auto calibration
Calibration broad Display 00.0 or 00.1 for 00, 20.0 ±1 for 20
Error ±1 at 0 to 15, ±1.5 at 16 to 25
Accuracy ≤6% preset value
Continuously variable ≤3%
Display Three digits LCD. The unit can be switched between mg/dl, umol/l freely.
Fast charging Three hours
Average measurement function 2 to 5 times
Power 3.7V
Voltage 380V, 50Hz
Dimension (L×W×H) 182×57×31mm
Weight 350G

Features

  • Non-invasive measurement
  • Portable design
  • Easy to operate
  • Intuitive interface
  • Long battery life and durability

Applications

  • Bilirubin Meter NBLM-102 measures bilirubin levels in newborns and infants without the need for blood sampling. It is applied in neonatal care units, pediatric clinics, and maternity hospitals.

Ask Expert

FAQ for Bilirubin Meter NBLM-102

1: Why does the Bilirubin Meter NBLM-102 use a xenon flash lamp as its light source?

The xenon flash lamp offers high-intensity, consistent illumination required for accurate light reflection. This ensures precise comparison between blue and green light to evaluate bilirubin levels effectively, even in varied lighting environments.

2: Is this device suitable for non-invasive bilirubin testing in newborns?

Yes, the Bilirubin Meter is designed for non-invasive bilirubin monitoring in neonates. It reduces the discomfort and risks associated with blood sampling, making it ideal for routine checks in neonatal and pediatric settings.

3: How does the average measurement function improve reliability?

By allowing 2 to 5 readings per session, the device calculates an average to minimize variability. This feature enhances diagnostic confidence, especially when monitoring borderline or fluctuating bilirubin levels.

4: How many uses can I get from a full charge?

You can perform at least 500 measurements per full charge, which supports continuous operation throughout the day. This long battery life is especially beneficial in high-volume hospital settings.

5: What should I do if readings seem inconsistent or vary too much?

Ensure the device sensor and skin are clean and properly aligned during measurement. Use the averaging function, avoid bright light exposure during testing, and check for correct unit positioning.


Bilirubin Meter NBLM-102

Bilirubin Meter NBLM-102

Related Models Of Bilirubin meter

Labnics Bilirubin Meters utilize advanced photometric technology to ensure accurate and reliable results. These meters require only a small sample volume, making testing efficient and convenient. They operate effectively across various temperature conditions for consistent performance. Our units offer reliable connectivity options, allowing easy data transfer and smooth integration. They require a minimal sample volume, providing accurate and efficient testing.